WSE-6370/6370K LuminoGraph III Lite_Chemiluminescence Imaging System
WSE-6370/6370K LuminoGraph III Lite
_Chemiluminescence Imaging System
Purpose and Application
-
Western blot, Dot blot
-
DNA gel
-
Bioluminescence
-
Protein gel (Colorimetric)
Features
-
AutoExposure
→ The suitable exposure time is automatically calculated and images are photographed and saved -
Auto contrast・Inverse image
→Control software and image analysis software is available for auto contrast and inverse image functions -
Simple icon, User-friendly
-
Auto exposing, Sum, etc. Various detection mode
-
User registration and personal folder: Simple an image file management
-
6 mega pixels high sensitive cooled CCD camera enables high resolution and sensitivity
-
F 0.8 high sensitive lens
-
CS Analyzer -ATTO Original analysis software
-
Windows PC installation
-
Housekeeping protein ratio Normalization function
-
Free updating(Software) service
-
Image analysis function
-
Revision of distortion bands pattern
-
Quantitative analysis of band signal intensities
LuminoGraph III Lite system
Easy to Use
User registration and file management
Register user ID and manage imaging files individually. Imaging files are saved in the logged-in user’s folder.
The captured image displayed in chronological order. You can export or delete multiple images by select a date.
Intuitive button
Select Application
Easy to capture. The menu is configured according to the applications
Enable Auto Exposure
The Auto Exposure function can be applied to all applications.
Easy to set for Fluorescent dye
One-click optimal settings for fluorescent dye
Simple Contrast adjustment
Powerful Auto Exposure
Auto Merge
Western blot auto exposure provides Auto Merge function. Easily check the M.W. of the target protein.
Easily capture low-sensitivity images with Set Area function
Many Imaging systems that support Auto Exposure capture images basis on the strongest signal to avoid saturation. For this reason, it may be difficult to detect target protein if you capture an image with a big difference in sensitivity or the nonspecific band's signal is strong.
ATTO Imaging systems, including the LuminoGraph III Lite, have Set Area function. Bands that exist in a selected area are detected. Images are saved as many as area selected.
Capture an image of samples at once with large differences in expression level
When capturing multiple blots, the exposure time is calculated for each specified area and each images are taken. Even the difference in the expression level is large, good results are obtained.
Detect samples with weaker sensitivity
If the target protein’s signal is weaker than other proteins such as non-specific bands, it’s difficult to detect. In this case, you can detect the target protein by setting the area.
High Sensitive Imaging
Improved performance
Performance is higher than our previous models. Noise is greatly reduced and sensitivity is increased. Even if you increase the binning level to detect weak signals, the device also detects the band cleanly.
High sensitivity
Adopted the lens and sensor that are the same as our high-end model. Lightweight, cost-effective, and high performance
F 0.8 lens suitable for high sensitivity imaging
Theoretically, the light collection efficiency increases as the inverse of the square of the F. But, the smaller the F value, the greater the gap between the theoretical value and measured value. This is due to the effect of microlens on the surface of the sensor. The LuminoGraph III Lite features a high sensitivity F0.8 fixed focal lens, with little distortion and maximum brightness.
Highly Reliable Results
Powerful quantification and wide dynamic range
A signal detection proportional to the amount of protein is required for the quantification of Western blot, and a wide dynamic range is required to detect weak signals.
The right graph shows the signal measured using a reference light source emitting a faint light. You can see the linearity of R2 value over 0.999.
The Luminograph III Lite has excellent lineality for the wide dynamic range, so it can be quantified simultaneously even if the difference in the expression level is large.
Superior reproducibility
To trust the results of the images captured, reproducibility is required that detect the same amount of signals equally.
The table on the left is the uncertainty produced by repeatedly captured images using a reference light source (WSL-1200 Kohshifundam) and analyzing the intensity of the image. It has excellent reproducibility within ± 0.2% uncertainty
WSL-1200 KohshiFundam
WSL-1200 KohshiFundam, our reference light source for validation, was used for reliability test.
1) Standard light source for verification with specified luminous flux
2) 11 step variation in light volume from 1/1 to 1/1024 by PWM (Pulse Width Modulation) control
3) Deal with the linearity test of photometric equipment
4) Suitable for reproducibility testing, as the amount of light is equal even with changes in environmental temperature
Quantitative Analysis
Densitometry CS Analyzer 4
This software performs various analysis such as intensity measurement, M.W. analysis, pI analysis, and relative quantity, etc. by selecting analysis modes according to sample types such as Lane, Spot, and Plate.
It also has the ability to adjust images such as image rotation, contrast adjustment, and merge, and the adjusted images can be stored in various formats.
You can save the analysis results as a CSV file that is available in MS Excel and save data in report format, including images and Standard curve, as PDF files.
Lane Analysis
Quantification of DNA gels or protein gels. Analyze bands and background automatically and calculate the intensity of bands of each lane.
Spot Analysis
Quantification of regions of interesting in western blotting, culture cells, or living organisms.
Plate Analysis
Quantification samples in microplate, array, or dot blotting.
Normalization
We support normalization that compares the relative abundance of a specific protein of blots that are captured separately. Use CS Analyzer instead of inconveniently calculate yourself.
Free Rotation
Enable easy leveling function. Draw a line which you want to make vertically by dragging a mouse.
Specification
Specification
Application
Nanjing Tansi Technology Co.,Ltd.
TEL: 025-85432178, 85432278
ADD:2-728b, Hongqiao center, new City Plaza, 281 Zhongshan North Road, Nanjing. ZIP:210009
E-mail:sales@tansi.com.cn
Tansi Beijing Branch
TEL: 010-62908712
ADD:Rm 719, Jinrongkemao Building, Shangdi 3rd Street, Haidian District, Beijing. ZIP:100085
WebSite:en.tansi.com.cn
© 2024 tansi.com.cn Copyright 苏ICP备05020058号